- Large Display Single Probe Fridge/Freezer Vaccine Temperature Data Logger with Software-Less Reporting
Data Loggers, Vaccine Temperature Monitors
- Logs: 24M
- Range: -50/70°C
- Accuracy: ±0.5°C
- Model: ACCRT8002
The TRED30-16 30 day logger with display.
A CDC / VFC compliant ISO/IEC 17025 NIST traceable temperature data logger for monitoring & recording temperatures of vaccines in refrigerators or freezers.
New large Easy-to-Read display to see the current, min and max temperatures and alarm status for up to 30 days at a glance.
The TRED30-16 CU measures and stores over 17,500 temperature readings over a range of -40 °C to +99 °C (-40 °F to +210 °F), with support for both Smart and traditional probes. Its display provides a clear, at-a-glance view of any temperature excursions within the current and past 59 days, alongside information such as current temperature, time, recording status, and battery life.
Pre-set alarm limits trigger a visual alarm, changing the status indicator from a ✓ to an ✗, with the option to sound an audible alert. A day marker also appears to ensure visible tracking of any temperature breaches.
Details of any excursions in the preceding 60 days can be checked directly by inspecting the statistics history on the loggers display or in more detail by downloading the logged data via a standard LogTag® Interface cradle to LogTag® Analyzer operating software.
![]()
| Catalog No. | DESCRIPTION |
|---|---|
| TRED30-16 CU | VFC Temperature USB-C Data Logger, -40/99C, SMART PROBE w/ buffer, ISO calibrated |
FEATURES:
| Product Model | TRED30-16U (Replaceable Battery) |
| External Sensor Measurement Range | -40 °C to +99 °C (-40 °F to +210 °F) |
| Operating Temperature Range | -30°C to +60°C (-22°F to +140°F) |
| Storage Temperature Range | -10°C to +40°C (14°F to +104°F) |
| Rated Temperature Reading Accuracy | Better than ±0.5°C (±0.9°F) for -20°C to +40°C (-4°F to +104°F), typically ±0.3°C (0.6°F). Better than ±0.8°C (±1.4°F) for -40°C to -20°C (-40°F to -4°F), typically ±0.5°C (0.9°F). Better than ±0.8°C (±1.4°F) for +40°C to +70°C (+104°F to +158°F), typically ±0.7°C (1.3°F). Better than ±1.2°C (±2.2°F) for +70°C to +99°C (+158°F to +210°F), typically ±1°C (1.8°F). Actual performance is typically much better than the rated values. Accuracy figures can be improved by recalibration. |
| Rated Temperature Reading Resolution | 0.1°C (0.2°F) for measurements -40°C to +50°C (-40°F to +122°F). 0.2°C (0.4°F) for measurements +50°C to +70°C (+122°F to +158°F). 0.3°C (0.5°F) for measurements +70°C to +80°C (+158°F to +176°F). 0.4°C-0.6°C (0.7°F to 1°F) for measurements +80°C to +99°C (+176°F to +210°F). LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®. |
| Sensor Reaction Time | Typically less than 2 minutes (T90) in moving air (1m/s) for ST100T, ST100H and ST100S types |
| Recording Capacity | 17,526 temperature readings. 60 days @ 5min logging. Day summary statistics memory (for display on LCD): up for 30 days of Max/Min/duration and alarm trigger statistics |
| Sampling Interval | Configurable from 30 seconds to hourly |
| Logging Start Options | Push button start or specific date and time. Optional start delay of up to 18 hours |
| Recording Indication | State indicator “RECORDING” |
| Download Time | Typically less than 10 seconds for full memory (17,526 readings) using the USB connection, depending on computer |
| Environmental | IP61 (when vertically mounted or hung) |
| Power Source | 3V CR2032 LiMnO2 coin cell battery, user replaceable |
| Battery Life | 1 year storage, followed by 1 year of operation with normal use (6 minute logging, statistics reviewed on the display no more than once daily for no longer than 30 seconds each time, download data monthly) NOTE: Continual activation of the audible alarm will reduce the working life of the battery. When an alarm is triggered, the alarm should be cleared and reset as soon as possible. |
| Real Time Clock | Built-in real time clock Rated accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day) Rated temperature coefficient is -0.034 ±0.006ppm/°C (i.e. typically +/- 0.00294 seconds/day/°C). |
| Standard Remote Sensor Cable Length | Standard: 1.5m (4’11″) Extended: 3m (9’10″) (Recommended maximum) |
| Remote Sensor Cable Type | PTFE (FDA food contact rated), coaxial |
| Size | 93mm(H) x 54.5mm(W) x 8.6mm(T) |
| Weight | 41g |
| Case Material | Polycarbonate |
Not applicable
CALL: (973) 300-9100
9am to 5pm est
The TRED30-16 30 day logger with display.
A CDC / VFC compliant ISO/IEC 17025 NIST traceable temperature data logger for monitoring & recording temperatures of vaccines in refrigerators or freezers.
New large Easy-to-Read display to see the current, min and max temperatures and alarm status for up to 30 days at a glance.
The TRED30-16 CU measures and stores over 17,500 temperature readings over a range of -40 °C to +99 °C (-40 °F to +210 °F), with support for both Smart and traditional probes. Its display provides a clear, at-a-glance view of any temperature excursions within the current and past 59 days, alongside information such as current temperature, time, recording status, and battery life.
Pre-set alarm limits trigger a visual alarm, changing the status indicator from a ✓ to an ✗, with the option to sound an audible alert. A day marker also appears to ensure visible tracking of any temperature breaches.
Details of any excursions in the preceding 60 days can be checked directly by inspecting the statistics history on the loggers display or in more detail by downloading the logged data via a standard LogTag® Interface cradle to LogTag® Analyzer operating software.
![]()
| CATALOG NO. | DESCRIPTION |
|---|---|
| LTUTRED3016 | VFC Temperature Data Logger, -40/99°C (-40/210°F). 16K logs, 3m Probe and Buffer Bottle |
FEATURES:
| Product Model | TRED30-16U (Replaceable Battery) |
| External Sensor Measurement Range | -40 °C to +99 °C (-40 °F to +210 °F) |
| Operating Temperature Range | -30°C to +60°C (-22°F to +140°F) |
| Storage Temperature Range | -10°C to +40°C (14°F to +104°F) |
| Rated Temperature Reading Accuracy | Better than ±0.5°C (±0.9°F) for -20°C to +40°C (-4°F to +104°F), typically ±0.3°C (0.6°F). Better than ±0.8°C (±1.4°F) for -40°C to -20°C (-40°F to -4°F), typically ±0.5°C (0.9°F). Better than ±0.8°C (±1.4°F) for +40°C to +70°C (+104°F to +158°F), typically ±0.7°C (1.3°F). Better than ±1.2°C (±2.2°F) for +70°C to +99°C (+158°F to +210°F), typically ±1°C (1.8°F). Actual performance is typically much better than the rated values. Accuracy figures can be improved by recalibration. |
| Rated Temperature Reading Resolution | 0.1°C (0.2°F) for measurements -40°C to +50°C (-40°F to +122°F). 0.2°C (0.4°F) for measurements +50°C to +70°C (+122°F to +158°F). 0.3°C (0.5°F) for measurements +70°C to +80°C (+158°F to +176°F). 0.4°C-0.6°C (0.7°F to 1°F) for measurements +80°C to +99°C (+176°F to +210°F). LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®. |
| Sensor Reaction Time | Typically less than 2 minutes (T90) in moving air (1m/s) for ST100T, ST100H and ST100S types |
| Recording Capacity | 17,526 temperature readings. 60 days @ 5min logging. Day summary statistics memory (for display on LCD): up for 30 days of Max/Min/duration and alarm trigger statistics |
| Sampling Interval | Configurable from 30 seconds to hourly |
| Logging Start Options | Push button start or specific date and time. Optional start delay of up to 18 hours |
| Recording Indication | State indicator “RECORDING” |
| Download Time | Typically less than 10 seconds for full memory (17,526 readings) using the USB connection, depending on computer |
| Environmental | IP61 (when vertically mounted or hung) |
| Power Source | 3V CR2032 LiMnO2 coin cell battery, user replaceable |
| Battery Life | 1 year storage, followed by 1 year of operation with normal use (6 minute logging, statistics reviewed on the display no more than once daily for no longer than 30 seconds each time, download data monthly) NOTE: Continual activation of the audible alarm will reduce the working life of the battery. When an alarm is triggered, the alarm should be cleared and reset as soon as possible. |
| Real Time Clock | Built-in real time clock Rated accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day) Rated temperature coefficient is -0.034 ±0.006ppm/°C (i.e. typically +/- 0.00294 seconds/day/°C). |
| Standard Remote Sensor Cable Length | Standard: 1.5m (4’11″) Extended: 3m (9’10″) (Recommended maximum) |
| Remote Sensor Cable Type | PTFE (FDA food contact rated), coaxial |
| Size | 93mm(H) x 54.5mm(W) x 8.6mm(T) |
| Weight | 41g |
| Case Material | Polycarbonate |